ST Standard Type

Setting & Operation

◆ 86mm Motor Drive(EzS-PD-86 series)

Status Monitor LED

1. Drive Status LED
Indication Color Function ON/OFF Condition
PWR Green Power input indication LED is turned ON when power is applied
INP Yellow Complete Positioning Motion Lights On when Positioning error reaches within the preset pulse selected by rotary switch
SON Orange Servo On/Off Indication Servo On: Lights On, Servo Off: Lights Off
ALM Red Alarm indication Flash when protection function is activated(Identifiable which protection mode is activated by counting the blinking times)
◆ Protection functions and LED flash times
Times Protection Conditions
1 Over Current Error The current through power devices in inverter exceeds the limit value*1
2 Over Speed Error Motor speed exceeds 3,000 [rpm]
3 Position Tracking Error Position error value is higher than 180˚ in motor run state
4 Over Load Error The motor is continuously operated more than 5 seconds under a load exceeding the max. torque
5 Over Temperature Error Inside temperature of drive exceeds 85℃
6 Over Regenerated Voltage Error Back-EMF is higher than limit value*2
7 Motor Connection Error The power is ON without connection of the motor cable to drive
8 Encoder Connect Error Cable connection error in Encoder connection of drive
10 In-Position Error After operation is finished, position error more than 1 pulse is continued for more than 3 seconds
11 System Error Error occurs in drive system
12 ROM Error Error occurs in parameter storage device(ROM)
15 Position Overflow Error Position error value is higher than 180˚ in motor stop state
* 1 : Limit value depends on motor model(Refer to the Manual)
* 2 : Voltage limit of Back-EMF depends on motor model (Refer to the Manual)
※ For the details, please refer to the Manual.
Alarm LED flash
(Ex, Position tracking error)

Switch

1. Pulse Input Setting Switch(SW1.1)
Indication Switch Name Function
2P/1P Selecting Pulse Input Mode Selectable 1-Pulse input mode or 2-Pulse input mode as Pulse input signal.
ON: 1-Pulse mode
OFF: 2-Pulse mode
※ Default: 2-Pulse mode
2. Rotational Direction Setting Switch(SW1.2)
Indication Switch Name Function
DIR Switching Rotational Direction Based on CW(+Dir signal) input to driver.
ON: CCW(-Direction)
OFF: CW(+Direction)
※ Default: CW mode

CCW Direction
Direction setting switch : ON

CW Direction
Direction setting switch : OFF

3. Resolution Setting Switch(SW3)

The Number of pulse per revolution. .

Position Pulse/Revolution
0 500*1
1 500
2 1,000
3 1,600
4 2,000
Position Pulse/Revolution
5 3,600
6 5,000
7 6,400
8 7,200
9 10,000*2
* 1 : Resolution of position “0” will be different according to the resolution of encoder adopted to the product. But in case of the encoder with 10,000[ppr] resolution, it will be set as 500.
* 2 : Default value of resolution will be the same as the resolution of encoder adopted to the product.
※ When selected resolution is more then encoder resolution, motor shall be operated by microstep between pulses.
4. Position Controller Gain Setting Switch(SW2)
The Position Controller Gain Switch allows for the correction of the motor position deviation after stopping caused by load and friction. Depending on the motor load, the user may have to select a different gain position to stabilize and to correct positional error quickly.

To tune the controller
1. Set the switch to “0” position.
2. Start to rotate the switch until system becomes stable.
3. Rotate the switch 1~2 position to reach better performance.
Position Time Constant of the Integral part Proportional Gain*1
0 1 1
1 1 2
2 1 3
3*2 1 4
4 1 5
5 1 6
6 2 1
7 2 2
8 2 3
9 2 4
A 2 5
B 3 1
C 3 2
D 3 3
E 3 4
F 3 5
* 1 : Value in the columns are in relative units. They only show the parameter changes depending on the switch’s position.
* 2 : Default = 3.
5. In-Position Value Setting Switch(SW4)
To select the output condition of In-Position signal, In-Position output signal is generated when the pulse number of positional error is lower than selected In-Position value set by this switch after positioning command is executed.
Position In-Position Value [Pulse]
Fast Response
0*1 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
Position In-Position Value [Pulse]
Accurate Response
8 0
9 1
A 2
B 3
C 4
D 5
E 6
F 7
* 1 : Default = 0.
※ Please refer to the Manual for setting.

Connector

1. Encoder Connector(CN2)
No. Function I/O
1 A+ Input
2 A- Input
3 B+ Input
4 B- Input
5 Z+ Input
6 Z- Input
7 5VDC Output
8 GND Output
9 F.GND -
10 F.GND -
2. Input / Output Signal Connector(CN1)
No. Function I/O
1 CW+(Pulse+) Input
2 CW-(Pulse-) Input
3 CCW+(Dir+) Input
4 CCW-(Dir-) Input
5 A+ Output
6 A- Output
7 B+ Output
8 B- Output
9 Z+ Output
10 Z- Output
No. Function I/O
11 Alarm Output
12 In-Position Output
13 Servo On/Off Input
14 Alarm Reset Input
15 NC -
16 BRAKE+ Output
17 BRAKE- Output
18 S-GND Output
19 EXT_GND Input
20 EXT_24VDC Input
3. Motor Connector(CN3)
No. Function I/O
1 A Phase Output
2 B Phase Output
3 / A Phase Output
4 / B Phase Output

No. Function I/O
1 / B Phase Output
2 B Phase Output
3 / A Phase Output
4 A Phase Output

※ 86mm Motor Drive

4. Power Connector(CN4)
No. Function I/O
1 24VDC Input
2 GND Input

No. Function I/O
1 GND Input
2 40~70VDC Input

※ 86mm Motor Drive

Connector Specifications

Connector specifications for cabling to drive.
Purpose Item Part Number Manufacture
Power
(CN4)
Housing
Terminal
5557-02R
5556T
MOLEX
Motor Drive Side
(CN2)
Housing
Terminal
5557-04R
5556T
MOLEX
Motor Side Housing
Terminal
5557-04R
5556T
MOLEX
Encoder Drive Side
(CN2)
Housing
Terminal
51353-1000
56134-9000
MOLEX
Encoder Side Housing
Terminal
SMP-09V-NC
SHF-001T-0.8BS
JST
Signal
(CN1)
Connector
Backshell
10120-3000PE
10320-52A0-008
3M
※ Above connector is the most suitable product for the drive applied. Another equivalent connector can be used.

Connector Specifications_ 86mm

Connector specifications for cabling to drive.
Purpose Item Part Number Manufacture
Power
(CN4)
Terminal Block AK950-2 PTR
Motor Drive Side
(CN3)
Terminal Block AK950-4 PTR
Motor Side Housing
Terminal
3191-4R1
1381T
MOLEX
Encoder Drive Side
(CN2)
Housing
Terminal
51353-1000
56134-9000
MOLEX
Encoder Side Housing
Terminal
SMP-09V-NC
SHF-001T-0.8BS
JST
Signal
(CN1)
Connector
Backshell
10126-3000PE
10326-52F0-008
3M
※ Above connector is the most suitable product for the drive applied. Another equivalent connector can be used.