BT Type

Settings and Operation_ Ezi-SERVOⅡ BT-28 Series

Ezi-SERVOⅡ BT-28 Series

Drive status LED

1. Drive Status LED
Status LED
Disable Green :  
Red :
Green light flashing, Red light of
Enable Green :  
Red :
Green light on, Red light of
In motion Green :  
Red :  
Green light on, Red light on
Inposition deviation Green :  
Red :    
Green and Red light alternately flashing
Alarm Green :
Red :  
Red light flashing repeatedly as many as alarm number
◆ Protection functions and LED flash times
Times Protection Conditions
1 Over Current Error The current through power devices in inverter exceeds 4.8A
2 Over Speed Error Motor speed exceeds 3,000 [rpm]
3 Position Tracking Error Position error value is higher than 180˚ in motor run state
4 Over Load Error The motor is continuously operated more than 5 seconds under a load exceeding the max. torque
5 Over Temperature Error Inside temperature of drive exceeds 85℃
6 Over Regeneratived Voltage Error Back-EMF is higher than 48V
7 Motor Connect Error The power is ON without connection of the motor cable to dre
8 Encoder Connect Error Cable connection error with Encoder connection in drive
10 In-Position Error After operation is finished, position error more than 1 pulse is continued for more than 3 seconds
12 ROM Error Error occurs in parameter storage device(ROM)
15 Position Overflow Error Position error value is higher than 180˚ in motor stop state
Alarm LED flash
(Ex, Position tracking error)

Connector

1. Power Input/Output Signal Connector(CN1)
NO. Function I/O
1 GND Input
2 24VDC Input
3 Tx Output
4 Rx Input
5 Alarm Output
6 In-Position Output
NO. Function I/O
7 Servo On/Off Input
8 Alarm Reset Input
9 CCW+(Dir+) Input
10 CCW-(Dir-) Input
11 CW+(Pulse+) Input
12 CW-(Pulse-) Input

Connector Specification

Connector specifications for cabling to drive.
Purpose Item Part Number Manufacturer
Signal Housing
Terminal
GHR-12V-S
SSHL-005T-P0.2
JST
※ Above connector is the most suitable product for the drive applied. Another equivalent connector can be used.

Settings and Operation_ Ezi-SERVOⅡ BT-42, 56, 60 Series

Ezi-SERVOⅡ BT-42, 56, 60 Series

Drive status LED

1. Drive status LED
Indication Color Function ON/OFF Condition
PWR Green Power input indication LED is turned ON when power is applied
ALM Red Alarm indication Flash when protection function is activated(Identifiable which protection mode is activated by counting the blinking times)
◆ Protection functions and LED flash times
Times Protection Conditions
1 Over Current Error The current through power devices in inverter exceeds the 4.8A
2 Over Speed Error Motor speed exceeds 3,000 [rpm]
3 Position Tracking Error Position error value is higher than 180˚ in motor run state
4 Over Load Error The motor is continuously operated more than 5 seconds under a load exceeding the max. torque
5 Over Temperature Error Inside temperature of drive exceeds 85℃
6 Over Regeneratived Voltage Error Back-EMF is higher than 48V
7 Motor Connect Error The power is ON without connection of the motor cable to dreiv
8 Encoder Connect Error Cable connection error with Encoder connection in drive
10 In-Position Error After operation is finished, position error more than 1 pulse is continued for more than 3 seconds
12 ROM Error Error occurs in parameter storage device(ROM)
15 Position Overflow Error Position error value is higher than 180˚ in motor stop state
Alarm LED flash
(Ex, Position tracking error)

Switch

1. Pulse Input Setting Switch(SW1)
Indication Switch Name Function
2P/1P Selecting pulse
input mode
Selectable 1-Pulse input mode or 2-Pulse input mode as Pulse input signal.
ON: 1-Pulse mode
OFF: 2-Pulse mode
※ Default: 2-Pulse mode
2. Resolution Setting Switch(SW3)

The Number of pulse per revolution.

Position Pulse/Revolution
0 500*1
1 500
2 1,000
3 1,600
4 2,000
Position Pulse/Revolution
5 3,600
6 5,000
7 6,400
8 7,200
9 10,000*2
* 1 : Resolution of position “0” will be different according to the resolution of encoder adopted to the product.
       But in case of the encoder with 10,000[ppr] resolution, it will be set as 500.
※ Selected resolution is more then encoder resolution, motor shall be operated by microstep between pulses.

Connector

1. Input/Output Signal Connector(CN1)
NO. Function I/O
1 CW+(Pulse+) Input
2 CW-(Pulse-) Input
3 CCW+(Dir+) Input
4 CCW-(Dir-) Input
5 A+ Output
6 A- Output
7 B+ Output
8 B- Output
9 Z+ Output
10 Z- Output
NO. Function I/O
11 Alarm Output
12 In-Position Output
13 Servo On/Off Input
14 Alarm Reset Input
15 NC -
16 BRAKE+ Output
17 BRAKE- Output
18 S-GND Output
19 EXT_GND Input
20 EXT_24VDC Input
2. Power Connector(CN2)
NO. Function I/O
1 24VDC Input
2 GND Input
3. Parameter Setting Communication Connector
NO. Function
1 Tx
2 Rx
3 GND

Connector Specification

Connector specifications for cabling to drive.
Purpose Item Part Number Manufacturer
Power
(CN2)
Terminal Block MC421-38102 DECA
Signal
(CN1)
Housing
Terminal
501646-2000
501648-1000(AWG 26~28)
MOLEX
Parameter setting
(CN3)
Housing
Terminal
3264-03
5263PBTL
MOLEX
※ Above connector is the most suitable product for the drive applied. Another equivalent connector can be used.